Skip to content

Data Center

Secure Your Data in our Top-Notch Facility

Umpqua Technologies operates a world-class data facility with cloud and colocation centers. The facility offers diversified power and efficient server cooling environments.

Our data center is staffed with the best local experts available to assist you with all your managed service’s requests. We also offer assistance during your transition to our facility by offering streamlined migration services – making your move as simple as possible.

Data Center / Colocation Specifications

FACILITY SPECIFICATIONS

Built in 2012, premium data center office and colocation space totaling 12,500 sq. ft. Data Center/Colocation floor space 5,000 sq. ft. Redundant N+1 power and cooling services specifically optimized for high-density deployments Multiple provider availability offering access to Tier 1 internet service Diverse fiber infrastructure available Customizable floor space to accommodate connectivity designs

BUILDING ACCESS AND SECURITY

24×7 escorted on-site entry Alarm system with secure video surveillance throughout the facility Multi-level access authorization with Card control and biometric verification level access

BUILDING ACCESS AND SECURITY

24×7 escorted on-site entry Alarm system with secure video surveillance throughout the facility Multi-level access authorization with Card control and biometric verification level access

POWER GENERATION

Redundant diesel generators Significant fuel supply availability to ensure continuous operation in the event of a long term utility power failure

COOLING

Chiller (Glycol) system with high efficiency air handler for efficient year round energy savings N+1 redundancy Zone setups designed for future 40 to 100 Gigabit connection speeds Hot-aisle and cold-aisle configurations with optional air containment solutions to increase efficiency and density while maintaining strict cooling standards

NETWORK CONNECTIVITY

Internet bandwidth active over multiple providers Dedicated redundant fiber connectivity to carrier hotel

SYSTEM MONITORING

Designed for State-of-the-art monitoring, providing real-time feedback on building cooling, heating, and customer links as requested Enabling easy system management and instant identification of problems with systems Monitoring includes power, cooling, leak detection, and network and systems infrastructure needs

ELECTRICAL POWER INFRASTRUCTURE

Phase 1a (Complete) 500Kw Diesel generator(s) (N+1) 225kVA UPS 51 tons (N+1) Cooling Data Center 180kW (IT Loads) Data Center 3 tons (N) Cooling Electrical Room 6 tons (N+1) Cooling Cross-Connect room 20kW (IT Loads) Cross-Connect Room Power Utilization Efficiency (PUE) 1.27 Phase 1b 750kVA UPS (N+1) 171 tons (N+1) Cooling Data Center 600kW (IT Loads) Data Center 9 tons (N) Cooling Electrical Room 11 tons (N+1) Cooling Cross-Connect room 40kW (IT Loads) Cross-Connect Room Power Utilization Efficiency (PUE) 1.29 Phase 2 500kVA UPS (N+1) Electrical room 1,100kVA UPS (N+1) UPS Room 540 tons (N+1) Cooling Data Center 1,480kW (IT Loads) Data Center 9 tons (N) Cooling Electrical Room 12 tons (N) Cooling UPS Room Power Utilization Efficiency (PUE) 1.14 Up to 3 MW of on-site power available at full build Redundant UPS infrastructure to prevent loss of critical power Overhead power distribution prevents interference with network infrastructure Offered capability of 12 KW per rack at full build.

FIRE DETECTION AND SUPPRESSION

Off-site alarm monitoring and fire department dispatch Multi-zoned Pre-detection air sensors Pre-action dry pipe fire suppression systems that only fill with water in the event that two or more sensors are triggered in the same zone Only discharges in area where the temperature or flame triggers fire sprinkler head